Riello UPS

Multi Switch ATS

1:1

Automatic Transfer Switch

Riello UPS Multi Switch ATS is a high availability intelligent switch that provides redundant power to connected equipment with two AC input sources. Multi Switch ATS supplies power to the connected loads from a primary mains source. If that primary source becomes unavailable, Multi Switch ATS automatically transfers loads to the secondary source.

2 models in this range · quoted to order by an authorized Riello UPS reseller

Multi Switch ATS

Highlights

  • Redundant power supply
  • Load protection
  • Versatile to use

Models & ordering

Riello model designations are the order codes. Each model is quoted to order; open a model for its full specification and to request pricing and lead time.

ModelRated powerActive powerDimensions (h w d)Weight
MTA 30A1U x 19” x 330 mm5 kgQuote
MTA 16A1U x 19” x 330 mm5 kgQuote

Ships from and sold by A5 IT.

Brochures and data sheets

Select file language
Input
Voltage180-264 (selectable)
Frequency50 / 60 Hz
Environmental
ColorRAL 5004
CommunicationRS232 / USB / Slot for communication interface / Relay contacts port
Protection ratingIP20
Other compliancesEN 62310-1 (safety) EN 62310-2 (electro-magnetic compatibility)
ProtectionsOvercurrent - overvoltage - undervoltage - protection against energy back-feed
Noise (at 1 m)< 35 dBA
Operating temperature0 °C - +40 °C
Storing temperature-10 °C up to +50 °C
Relative humidity5-95% non-condensing
Output sockets30 A on Terminal board and 4 IEC-320 C13 (10 A) + 1 IEC-320 C19 (16 A)
Data
Weight5 kg
Dimensions (h w d)1U x 19” x 330 mm

Characteristics

Operating principle Multi Switch ATS provides direct distribution of eight 10 A IEC outputs or one 16 A IEC output in the 16 A model, four 10 A IEC outputs one 16 A IEC output or a terminal board in the 30 A model in a system with two input power lines (two mains inputs, or two UPS). Multi Switch ATS is able to connect to either of the two input power lines, whilst simultaneously monitoring the power uptake.

protection against load faults If one of the loads fails (e.g. short circuit), the Multi Switch ATS disconnects the group of sockets where the load is connected, thus preventing other loads from being switched off (i.e. in the event of poor discrimination of the protection devices).

Protection against power supply faults If one of the two power sources falls outside tolerance levels, Multi Switch ATS will transfer the load to the second power source (switching is instantaneous if the two sources are in phase).

Features

  • Full protection for loads against mains and load failures;
  • Redundant power supply;
  • Versatile to use: Multi Switch ATS can be powered with 2 different power supplies (including 2 UPS of different sizes/types);
  • 19” cabinet installation;
  • Display panel;
  • Can be connected to PowerNetGuard supervision software;
  • No signal connection between the Multi Switch ATS and the power sources or loads is necessary;
  • Compatible with PowerShield 3 software Slot for communications boards: the optional network card allows for remote in network connectivity, and management through HTTP, SNMP, and SSH protocol.